Products

  • GDGK-501 DC Power Supply

    GDGK-501 DC Power Supply

    GDGK-501 supplies power to circuit breakers or other HV switches.

  • GDHG-106B CT/PT Analyzer

    GDHG-106B CT/PT Analyzer

    GDHG-106B is a multifunctional tool specially designed for analyzing current transformers and voltage transformers of protection or measurement use. The operator only needs to set values for test current and voltage, the instrument will automatically boost voltage and current, and then show test results in a short time. Test data can be saved, printed, and uploaded to PC through USB interface.

  • GDHG-108A CT/PT Analyzer

    GDHG-108A CT/PT Analyzer

    GDHG-108A CT/PT Tester supports test voltage method to test bushings CTs which installed on transformer or inside switch-gear, suitable for the laboratory and on-site detection. 

  • GDHG-201P CT/PT Analyzer

    GDHG-201P CT/PT Analyzer

    GDHG-201P CT/PT Analyzer is a lightweight, portable unit capable of testing both current and voltage transformers.

    • CT testing includes Excitation Characteristic Test, Knee Points, Turn Ratio, Polarity, Secondary Winding Resistances, Secondary Burden,Ratio Error, Angular Difference
    • VT testing including Excitation Characteristic Test, Knee Points, Turn Ratio, Polarity, Secondary Winding Resistances, Ratio Error, Angular Difference

     

     

     

  • GDCY-20B 20kV Impulse Voltage Tester (Basic Type)

    GDCY-20B 20kV Impulse Voltage Tester (Basic Type)

    GDCY-20B Programmable Automatic Impulse Voltage Tester is mainly based on TB/T 2653, GB/T 17627, GB/T 16927, GB14048, GB7251, GB/T 16935, IEC 61730, GB4706, GB3048, JB/T 7083 and other standard requirements.

     

  • GDCY Impulse Voltage Test System (100kV-7200kV)

    GDCY Impulse Voltage Test System (100kV-7200kV)

    Impulse Voltage Test System is mainly used for carrying out full wave lightning impulse voltage test, chopping impulse test and switching impulse test on HV apparatus such as transformers, surge arrester, insulators, bushings, capacitors, and switches. It can generate standard lightning wave, switching wave, chopping wave with wide range voltage and energy.

     

     

     

  • Impulse Voltage Test System – High Voltage Test Instruments

    Impulse Voltage Test System – High Voltage Test Instruments

    GDCY series Impulse Voltage Generator can produce a wide range of voltage and energy to simulate waveform such as lightning impulse, lightning clipped wave, switching impulse and so on, enable to carry out various forms of impulse test for high voltage power equipment, cooperate with steepening device can carry out steep wave test on the insulator (insulator string).

     

  • GDCL-Series Impulse Current Generator(Customizable)

    GDCL-Series Impulse Current Generator(Customizable)

    The impulse current generator is mainly generating lightning impulse current 8/20μs, suitable for measuring residual voltage of surge arrester, varistors and other science research test.

     

     

  • GDCY-20P Impulse Voltage Test System

    GDCY-20P Impulse Voltage Test System

    The equipment is according to impulse voltage testing requirement of the low-voltage power distribution system SPD II product and solar battery, enable to generate impulse voltage (1.2/50μs), is used for grade III test and limiting voltage test of SPD and components. It is also used for impulse current test and residual voltage test of the MOV valve plate, unit and surge protective device(SPD), or used in other scientific research experiments.

    The equipment uses touch screen and PLC control technology, and the main performance meets the needs of domestic and foreign SPD products and their components for various combination wave testing.

  • GDCY-1000kV/100kJ Impulse Voltage Test System

    GDCY-1000kV/100kJ Impulse Voltage Test System

    Impulse Voltage Test System is mainly used to generate lightning impulse voltage, to research and check the ability of lightning impulse ability of electric equipment. It can generate standard lightning waveform and chopping waveform.

    The system can be used for impulse voltage test and other scientific research on GIS, cable, insulators, air gap, bushing, transformers etc.

  • GDCL-V 20kV/10kA Impulse Combination Wave Test System Technical Solution

    GDCL-V 20kV/10kA Impulse Combination Wave Test System Technical Solution

    The equipment is according to combination wave testing requirement of the low-voltage power distribution system SPD II product, enable to generate impulse voltage (1.2/50μs) and impulse current (8/20μs), is used for grade III test and limiting voltage test of SPD and components.