Partial Discharge Measurement Device

  • GDPD-3000C Portable Partial Discharge Detector

    GDPD-3000C Portable Partial Discharge Detector

    GDPD-3000C Portable Ultrasonic Partial Discharge Detector uses advanced cloud computing and automatic modeling technology to achieve the partial discharge signal measurement, recording, transmission, storage, analysis and exchange, providing powerful technical support for on-site measurement of partial discharge.

  • GDUVI-41  UV Imager

    GDUVI-41 UV Imager

    GDUVI-41 UV imager adopts ergonomic design and key operation, which is very suitable for daily maintenance of various high-voltage electrical equipment. The instrument adopts solar-blind technology to simultaneously image the visible light and ultraviolet light paths, and realizes the location of the ultraviolet light-emitting position through the real-time synchronous fusion of the two images, which can be detected around the clock. The video display can display the ultraviolet video and the visible light video separately, or the superimposed composite video, which can count the ultraviolet light spots in the selected range and provide the measurement data.

  • GDPD-414 Portable Partial Discharge Detector

    GDPD-414 Portable Partial Discharge Detector

    The GDPD-414 Portable Partial Discharge Detector adopts Smart Quick intelligent power test system , and is a portable local discharge inspection tool for live high voltage insulation equipment.

     

     

     

     

  • GDPD-PTU PD Online Monitoring System for Oil Transformer

    GDPD-PTU PD Online Monitoring System for Oil Transformer

    The aging and damage of the internal insulation of the transformer mostly starts from local discharge. The reason for local discharge is that the electric field is too concentrated at a certain point, or the electric field strength at a certain point is too large. At present, the main methods for detecting transformer local discharge faults are: UHF ultra-high frequency monitoring method, HFCT high-frequency pulse current local discharge measurement method (pulse current method), ultrasonic local discharge measurement method (ultrasonic method), and oil gas chromatography analysis method.

  • GD-610C Remote Ultrasonic Partial Discharge Detector

    GD-610C Remote Ultrasonic Partial Discharge Detector

    The GD-610C remote ultrasonic partial discharge detector uses an ultrasonic spectrum probe (sensor) to collect ultrasonic signals and analyze the sound of signals to diagnose faults, it is a diagnosis device for the accident of the distribution line.

     

  • Partial Discharge Online Monitoring System of GIS

    Partial Discharge Online Monitoring System of GIS

    Gas-insulated metal-enclosed switches (GIS) and gas-insulated metal-enclosed transmission lines (GIL) are one of the most important devices in the power system. They have the dual tasks of control and protection. 

  • Partial Discharge Online Monitoring System of Generators

    Partial Discharge Online Monitoring System of Generators

    Generally, partial discharge occurs at a position where the properties of the dielectric material are not uniform.

  • GDJF-2006 Partial Discharge Analyzer

    GDJF-2006 Partial Discharge Analyzer

    GDJF-2006 Digital Partial Discharge Detector is widely used for detecting partial discharge of high voltage equipment such as power transformers, instrument transformer, HV circuit breaker, Zinc oxide surge arrester, power cable. It also can make type tests and monitor insulation operation.

  • GDPD-313P Hand-held Partial Discharge Detector

    GDPD-313P Hand-held Partial Discharge Detector

    The hand-held partial discharge detector is used to detect and measure the instantaneous ground voltage discharge and surface discharge in the switch cabinet and display the discharge waveform and discharge amount in real time on the LCD screen. The instrument adopts a pistol-portable design, which can be scanned and detected directly on the switchgear shell without any influence or damage to the operation of the switchgear. At the same time, the measured signals can be stored and played back on the TF card. The matching headphones can hear the sound of the discharge.

Send your message to us:

Write your message here and send it to us