-
GDSD-140 Dielectric Strength Test Set For Insulation Sample
GDSD-140 test device is mainly suitable for making breakdown strength and withstand voltage test of solid insulating materials (such as: plastic, rubber, laminated materials, films, resins, mica, ceramics, glass, insulating paint and other insulating materials and insulating parts) under power frequency voltage or DC voltage.
The electronic control system of the device is controlled by PLC, and the data collection method is photoelectrically isolated, which effectively solves the anti-interference problem in the test process. The man-machine operation is convenient, and the dynamic curve can be displayed in real time.
-
GIT-450kVA/150kV PD-free AC Dielectric Test Set
The GIT-450kVA/150kV PD-free AC Dielectric Test Set is an advanced automatic withstand voltage tester designed in accordance with the latest national power industry standards. It utilizes PLC controller technology, 2.4G ISM networking, and an advanced human-machine interface. This test equipment is suitable for power frequency withstand voltage testing and partial discharge testing of high-voltage electrical equipment of 150kV and below.The max. capacitance of tested object is 0.05μF at 150kV.
-
GDYT-10/100 Partial Discharge Testing System 10kVA/100kV
This set of equipment is mainly used for partial discharge measurement and other scientific experimental research.
-
GDYD-D AC Dielectric Test Equipment With Manual Control Unit
AC Hipot testing is the effective and direct way to test insulation strength for electric equipment, apparatus, or machines. It checks dangerous flaws which assure electric equipment continuous working.
-
VLF AC Hipot Test Set
Withstand voltage test is an essential preventive test for electrical equipment. It is divided into two parts: AC and DC withstand voltage test.
-
Hipot Test Set With Automatic Control
AC hi-pot testing is the effective and direct way to test insulation strength for electrical equipment, apparatus or machines. It checks dangerous flaws which assure electrical equipment continuous working.
-
GDYD-M AC Dielectric Test Equipment with manual control unit
Typical applications include testing of transformers, switchgear, cables, capacitors, aerial motors platforms, hot sticks bucket bricks, vacuum bottles and other related equipment like vacuum interrupters, blankets, ropes, gloves, hydraulics hose, instruments transformers generators.
-
VLF AC Hipot Test Set 80kV
Withstand voltage test is an essential preventive test for electrical equipment. It is divided into two parts: AC and DC withstand voltage test.
-
GDYD-53A Automatic AC/DC Hipot Test Set
AC/DC Hipot testing is the effective and direct way to test insulation strength for electrical equipments,apparatus or machines. It checks dangerous flaws which assure electrical equipment continuous working.
-
GDJS-65 Insulation Materials Hipot Test Set
It is used to test insulation performance for insulation gloves, boots, mats, hats, rod, Electroscope etc. It can test 6pcs insulation gloves/boots at the same time, also 5pcs insulation rods.
-
Partial Discharge Test System GDYT series
It widely used in electrical manufacturing, power operation departments, research institutes and universities.
-
GDTF-2700kVA/900kV AC Resonant Test System
GDTF-2700kVA/900kV is specially designed for AC withstand voltage test for 500kV or below switch, GIS, instrument transformers and neutral point of main transformers.The system includes Variable frequency power supply, exciting transformer, reactor, and capacitive voltage divider.